SMARTbrick 2400A – 4-20mA CURRENT INPUT
For evaluation of current outputs
A single-channel current measuring module with galvanic isolation is used to analyse power outputs. A load resistance of 75 Ohm is used for current analysis. A line break and a short circuit can be stimulated for error stimulations. The error stimulation is specified in connection with the carrier board via CAN bus.
Channels | 1 |
Input Voltage | 24 VDC |
Input Current | 4 mA – 20 mA |
Max. permissible total error | ± 0.1 mA |
Max. short circuit current | 50 mA |
Internal resistance in short circuit | max. 3.5 Ω |
Load resistance | 75 Ω ± 5 Ω |
Insulation voltage | max. 50 VDC |
Insulation Resistance | 1 MΩ |
ADC Resolution | 12 Bit |
Modulfunctions | |
Error stimulation “line breakage” | via software |
Error stimulation “Short circuit” | via software |
Display of error stimulies | via LED’s |
Additional Products
![]() |
SLSC-14XX Modular Cards |
Contact
You have questions? Our team is always happy to answer your questions: +49 7522 916 87 600
Or just write an E-Mail to smartbrick.support@smart-e-tech.de.