SMARTbrick 2400A – 4-20mA CURRENT INPUT

For evaluation of current outputs

A single-channel current measuring module with galvanic isolation is used to analyse power outputs. A load resistance of 75 Ohm is used for current analysis. A line break and a short circuit can be stimulated for error stimulations. The error stimulation is specified in connection with the carrier board via CAN bus.
Channels 1
Input Voltage 24 VDC
Input Current 4 mA – 20 mA
Max. permissible total error ± 0.1 mA
Max. short circuit current 50 mA
Internal resistance in short circuit max. 3.5 Ω
Load resistance 75 Ω ± 5 Ω
Insulation voltage max. 50 VDC
Insulation Resistance 1 MΩ
ADC Resolution 12 Bit
Modulfunctions
Error stimulation “line breakage” via software
Error stimulation “Short circuit” via software
Display of error stimulies via LED’s

Additional Products

SET-14XX Modular Cards
SLSC-14XX Modular Cards

Contact

You have questions? Our team is always happy to answer your questions: +49 7522 916 87 600
Or just write an E-Mail to smartbrick.support@smart-e-tech.de.