SET-1210
Resistor Simulation Card

Powerful solution for applications requiring simulation of resistive sensors

The SET-1210 Resistor Simulation Card provides a powerful solution for applications requiring simulation of resistive sensors.

The SET-1210 Card covers two ranges of values that meet the needs of most functional test systems.

It is designed to applications such as the testing of engine controllers where resistive sensors provide information on parameters such as temperature.

Each channel of the SET-1210 Resistor Simulation Card is able to simulate the common short circuit and open circuit conditions that can be experienced in a system due to faulty wiring or sensors.

Features

  • 16 channels
  • Very High Accuracy and Stability
  • Bipolar resistor emulation
  • Fully Programmable with a Choice of Resistance Ranges
  • Low Thermo-Electric EMF
  • Simple Verification with an External DMM
  • Suitable for Sensor Emulation Applications
  • Fully Programmable using Resistance Calls to the Driver
  • Supported by National Instruments SLSC Chassis
  • Configurable in small discrete steps, tunes stepless
  • Short and open circuit simulation

Absolute Maximum Ratings

Condition Value
Relative Humidity Non-condensing 5% – 95%
Temperature 0 °C – 85 °C
Storage -40 °C – 100 °C
Max Input Voltage Any Pin 60 V
Transient 65 V
Min Input Voltage Any Pin -60 V
Transient -65 V

Signal Card

R Range V Range I Range
Range 1 10 Ω – 10 kΩ ±0 – 25 V ±0 – 10 mA
Range 2 1 kΩ – 1 MΩ ±0 – 25 V ±0 – 10 mA

Absolute Maximum Ratings

Condition Value
Channels 16
Resistance 10 Ω to 10 kΩ
Current ±0 – 10 mA
Voltage ±0 – 25 V,
Possible higher
Overall Accuracy ±0.0005 A – ±10 mA
15°C -50°C
< 30%
Overall Accuracy ±0.0001 A – ±10 mA
15°C -50°C
< 15%
Overall Accuracy ±0.0005A – ±10 mA 50 Ω to 10kΩ
15 °C – 50 °C
< 6%,
PT100 Range -125°C to max
Overall Accuracy ±0.0001 A – ±10 mA 50 Ω to 10 kΩ
15 °C – 50 °C
< 3%,
PT100 Range -125 °C to max
Resolution 0.2 Ω / LSB, possible lower
Settling Time < 10 ms, possible lower

Absolute Maximum Ratings

Condition Value
Resistance 1 kΩ to 1 MΩ
Current ±0 – 10 mA
Voltage ±0 – 25 V, possible higher
Overall Accuracy 1 kΩ – 10 Ω
100 µA – 10 mA
< 6%, possible < 5%
Overall Accuracy 10 kΩ – 1 MΩ
1 mA – 10 mA
< 0,2%, possible 0,1%
Overall Accuracy 1 kΩ – 10 kΩ
1 mA – 10 mA
< 1%
Overall Accuracy 100 kΩ – 1 MΩ
10 µA – 10 mA
< 2%
Resolution 20 Ω / LSB, possible lower
Settling Time < 10 ms, possible lower

Applications

  • Enables DUT characterization required in parametric testing
  • RTD and Strain Gauge Simulator
  • HIL Testing
  • Simulation industrial sensors and actuators
  • Simulation of the internal resistance of i.e. lambda sensors
  • Simulation of engine temperature sensors

Contact

You have questions? Our SLSC support team is always happy to answer your questions.
Just write an E-Mail to slsc.support@smart-e-tech.de or call +49 7522 916 87 600.