SET-2310
Line Fault Modul
Bundling test signals on the fault buses
The main function of the plugin SET-2310 Line Fault Daughter Module is to multiplex test signals on the fault buses. On any SET approved SLSC Card with a plugin module slot, the Line Fault Daughter Module can be easily mounted. With 32 single-ended or 16 differential channels, the SET-2310 provides fault connection capabilities in a small form factor. The fault bus of the Daughter Module directs to the base cards connector to connect any fault device. It is possible to connect two fault signals to the two channel fault bus.
Absolut Maximum Ratings
Condition | Value | Comment | |
Relative Humidity | 5% to 95% | Non-condensing | |
Temperature | 0° C to 85° C | ||
Storage | -40° C to 85° C | ||
Max. Input Voltage | Any Pin | 60 Vdc | |
Min. Input Voltage | Any Pin | -60 Vdc | |
Max. Switching Power | DC, Resistive load | 60 W | |
Max. Current Rating (Channel Relais) | 1.5 A | ||
Max. Current Rating (BUS Relais) | 8 A |
Technical Data
Condition | Value | |
Update Time | 10 ms | |
Max Initial Contact Resistance | X1 -> X2 | 300 mΩ |
Expected Electrical Lifetime | 1 A, 30 Vdc resistive | Min 105 operations |
Expected Electrical Lifetime | 1,5 A, 30 Vdc resistive | Min 104 operations |
Physical Characteristics
Condition | Value | Comment | |
Module dimensions | 10 mm x 52 mm x 235 mm (H x W x D) | Standard Module size | |
Connector to Front | 2×20 pin female socket terminal strip | ||
Connector to Back | 2×20 pin terminal strip |
Environmental
Condition | Value | |
Operating Humidity | Relative, non-condensing |
10% to 90% |
Storage Humidity | Relative, non-condensing |
5% to 95% |
Operating Temperature | Forced-air cooling from chassis | 0° C to 40° C |
Storage Temperature | -40° C to 85° C | |
Maximum Altitude | 2000 m |
Plug-in module for the SET-2010 routing card
Additional products
![]() |
![]() |
![]() |
SLSC-2010 Routing Card | SET-2210 Instrument Modul | NI SLSC Chassis |
![]() |
![]() |
![]() |
SLSC Rack Breakout | HD44 Breakout | RTI Strain relief |
Contact
You have questions? The support team of National Instruments is always happy to answer your questions.
To NI Support.